Due to properties like size and molecular density, synapses and other structures of interest to neuroscience researchers have been difficult to study by conventional methods of microscopic investigation. Yet extracting information about the spatial organization, stoichiometry, interactions, and dynamics of these structures on a molecular level is essential; advancing our understanding of the human brain depends on developing more and better methods to do so.
Ideal neuroscience microscopy methods should not only achieve higher resolutions than conventional means, but also distinguish specific structures and provide complete and reliable information for multiple sample types.
In providing exactly these capabilities, super-resolution microscopy with single-molecule localization (SMLM) has overcome many of the limitations of conventional neuroscience microscopy. This has already enabled dramatic improvement of our understanding of neuronal and brain function and will continue to create new opportunities for investigation and discovery in the field going forward. Only the Vutara VXL provides unparalleled SMLM capabilities for neuroscientists.
TABLE OF CONTENTS
Neuroscience researchers face a unique challenge when selecting an imaging methodology: historically, no single method has been able to provide complete information about neuronal structures and processes at the molecular level, so selecting one has required compromising between capabilities or conducting complementary investigations via multiple methods.
For example, many structures of interest are barely visible or undiscoverable by methods that are capable of specific labeling, like diffraction-limited two-photon microscopy. Yet electron microscopy, which provides superior resolution and is the only method capable of visualizing structures of interest smaller than 50 nm — like the synaptic cleft and synaptic vesicles — lacks fluorescence microscopes' capability for easy protein-labeling of specific structures.1,2 This restricts researchers' opportunities to perform complex investigations, including protein identification or neuronal tracing.
Contrasting conventional methods of neuroscience microscopy, super-resolution microscopy both enables target-specific fluorescence labeling and achieves resolutions well below the diffraction limit of light microscopy. As a result, it can provide unique and often otherwise inaccessible insights into structures and processes.
Among the various super-resolution imaging techniques used in neuroscience research — including structured-illumination microscopy (SIM), stimulated emission-depletion (STED), and expansion microscopy — SMLM is the only method that relies entirely on analysis of the molecules imaged. SMLM also provides the highest resolution.3 As a result, with its lateral resolution of 20 nm and specific fluorescence labeling, SMLM is an exquisite tool to advance neuroscience.
Find out more on our 3D Imaging with Bi-Plane page.
As a result of its advantages in labeling specificity and resolution, SMLM has the potential to be highly applicable to many questions of interest to neuroscience researchers and SMLM techniques have already been used in a broad range of neuroscience applications.
To date, the results of these studies have demonstrated the applicability of the method to both structural and quantitative analysis as well as 3D imaging of both tissue and cultured samples.3 In these applications, SMLM has been able to provide insight into the spatial organization, stoichiometry, and temporal dynamics of a broad range of structures and processes and provides significant advantages over other methods for investigating molecular interactions (molecular size, density, distance apart, overlap, etc.).
SMLM studies demonstrated on tissue samples appear less frequently in SMLM literature than those demonstrated on cultured cells. This imbalance is especially apparent for applications that call for 3D imaging in tissue, and can be attributed to several sources of frustration for researchers. These include:
As a result, the achievable imaging depth of SMLM techniques can create challenges for working with tissue slices and thick samples.*
*Some instrumentation achieves superior imaging depth, especially for 3D imaging in tissue samples
(see "Advantages of Bruker's Vutara VXL for Neuroscience Applications" for more information).
Retinal Tissue Slice to Study Neural Development
MAGENTA: CALBINDIN; CYAN: PSD95
Retinal Tissue Slice to Study Neural Development
CALBINDIN
Retinal Tissue Slice to Study Neural Development
PSD95
C. elegans as Model System for Synaptic Transmission
C. elegans as Model System for Synaptic Transmission
Depending on the equipment, sample, and fluorophore is used, SMLM methods have the potential to achieve high lateral localization precisions and ~20 nm spatial resolution. Yet the actual resolution and localization precision achieved when imaging both cultured samples and tissue slices depend on a variety of additional factors. These include, among others, labeling density and accuracy, signal size and strength, and microscope drift. Optimizing sample praparation methods for SMLM by, for example, increasing labeling antibody concentration, can resolve many of these issues and clear the way for successful analysis.
The components and functionality of an SMLM imaging system itself can limit the resolution and localization precision achievable by any of the various SMLM techniques — especially when performing 3D imaging in tissue slices. Moreover, SMLM-capable microscopes can require time-consuming setup that distracts from critical research processes. They also often pair with analytical tools that lag behind their imaging capabilities.
Given the potential for instrument configuration to arbitrarily constrain the achievable results of SMLM investigation, it is important to select equipment with known capabilities that align with your specific research goals. Features frequently credited with providing the greatest opportunity for success and enabling researchers to take full advantage of the benefits of SMLM for neuroscience applications include:
Bruker's Vutara VXL offers best-in-class ease of use and imaging depth, supporting a broad range of different experimental needs. Key features include:
All SMLM methods rely on the selective on-off switching of fluorescent molecules. Classical STORM uses dye pairs (e.g., Cy3-Cy5), while dSTORM6 (direct STORM) requires only one fluorophore (e.g., Alexa647, Cy5) and a "switching buffer." Nevertheless, in both STORM and dSTORM, illumination with different wavelengths switches these fluorescent dyes on and off.
The advantage of STORM7 over PALM is that these dye molecules are highly efficient with large photon budgets, where the photo-activated proteins used in PALM emit a limited number of photons irreversibly photobleaching. As a result, STORM can achieve higher resolutions.
Similar to STORM, PALM uses photo-activatable fluorescence proteins (e.g., paGFP, mEOS2), which can be easier than labeling with photoswitching dyes. These proteins are switched on with one laser wavelength and imaged and then bleached with another.
The primary difference between PALM and STORM -- to the advantage of PALM -- is that it allows protein labeling at the endogenous level. Moreover, because other SMLM techniques provide many localization events per molecule, PALM, which provides a single localization event per molecule, is often more applicable for experimental objectives related to stoichiometry/true moleculart counting.
EXAMPLE APPLICATIONS OF THIS TECHNIQUE
The other SMLM techniques require sequentially staining target biological structures and repeatedly imaging them to produce a composite image. In PAINT methods, fluorophores are no longer permanently bound to targets, but rather float in buffer solution. Instead of a laser, transitioned binding and immobilization of labels (e.g., Nile red) out of the buffer to the investigated structure provide the on-off mechanism. This allows imaging of an unlimited number of structures of interest in the same sample and makes PAINT methods easier and more efficient to implement than other SMLM methods.
While photobleaching diminishes the photon budget of the chromophores used for labeling structures in other SMLM techniques, PAINT10 methods are immune to photobleaching. As a result, PAINT methods can achieve a higher spatial resolution than other techniques.
EXAMPLE APPLICATIONS OF THIS TECHNIQUE
In single particle tracking, individual particles are tracked as they move around a living cell. The kind of tracked particles can vary. Single particle tracking was the first Single Molecule localization technique to be published, in a seminal work, a fluorescent bead was affixed to myosin, and its step-size determined. Beads can be affixed to biomolecules of interest either chemically or by interaction with e.g. an antibody. But many other single particle tracking techniques have been developed. In SPT-PALM, a portion of a population of proteins are photoconverted or photoactivated, and tracked until they bleach – this technique allows for tracking the dynamics of endogenous proteins with the cell. SPT is not limited to proteins – systems such as SP2, RNA Aptamers such as Peppers, or non-catalytic dCAS9 can be used to track the production, location and movement of RNAs, and dCAS9 or the LacI/Lac-O system the precise location of gene loci within chromatin as well. On the Vutara VXL, two or more classes of biomolecules can be tracked simultaneously in 3D with our dual camera accessory. The VXL is particularly well suited to single particle tracking as all particles within a roughly 1 micron Z section a 50x50 micron field of view can be localized and tracked natively in 3D at very high temporal resolution, and our powerful SRX software will handle the particle tracking for you.
EXAMPLE APPLICATIONS OF THIS TECHNIQUE