MRMS

solariX

The workhorse platform for high-field MRMS work at 12T or 15T – useful for ultra-complex mixture analysis such as petroleomics and dissolved organic materials.

Routine IFS

for unambiguous results

solariX

Routine IFS for unambiguous results

Routine IFS
achieved by cutting edge XR technology.
Confident
results by reading the elemental composition.
MRMS technology
leadership for your application.
solariX

Achieve routine IFS by cutting edge technology

Compared to other FTMS techniques, the solariX and solariX 2xR feature a combination of latest MRMS, ParaCell and Magnetron control technology. This is prerequisite for the highest possible mass spec resolving power available and results in routine access to Isotopic Fine Structure (IFS) information for a broad mass range.

Patented ParaCell detector
The ParaCell is the enabling technology for solariX XR and 2xR. This detector concept is a departure from traditional MRMS cell strategies and provides uncommon broadband ion stability resulting in resolution orders of magnitude above other detection schemes. The ParaCell in combination with Absorption Mode Processing algorithms is the prerequisite for routine access to IFS information.

2xR technology realizes scientific visions and increased productivity
Bruker’s 2xR solariX instruments uses magnetron control technology and a newly developed, high sensitivity, low noise preamplifier, realizing scientists long standing vision to exploit harmonics detection schemes and thus increasing the experimental speed and instrument productivity.

Optional ESI/MALDI dual source
solariX series instruments allow for operation of a unique ESI/MALDI dual source. This optional source can either run liquid samples introduced via the electrospray ionization (ESI) source or from MALDI samples. This highly sensitive MALDI source uses Bruker’s smartbeam-II laser technology and provides several small focus diameters for various applications with different sample preparation techniques. Fast switchover between MALDI and ESI operation is controlled by a software push button, so even simultaneous ESI/MALDI operation is possible.

solariX

The power to see the unseen

Read the elemental composition for confident results
IFS delivers an additional dimension of information missing in data from other types of mass spectrometers. Exploiting solariX XR and solariX 2xR IFS capability, not only is the mass of the analyte measured but also its elemental constituents pinpointed. Combined with Brukers SmartFormula algorithms, assignment of sum formulas can be done with utmost confidence.

Leverage MRMS technology leadership for your application

  • 7T solariX XR MALDI instruments with its unique ESI/MALDI dual source are the definitive standard for label-free small molecule MALDI imaging studies. This allows for mapping of the localization of drugs and metabolites and providing spatial correlation with omics studies.
  • Flow Injection Analysis (FIA) MRMS workflows with 7T solariX 2xR simplifies and accelerates sample throughput in phenomics and discovery metabolomics by omitting time consuming chromatography.
  • Understanding the molecular compositional of petroleum allows for the prediction of its behavior and properties as well as environmental fingerprinting. Molecular classification using high end 15T MRMS systems solves problems of petroleum processing.
eXtreme Resolution reveals true heteroatom content
solariX

Discover previously hidden information to proof your results

Bruker's eXtreme Resolution Magnetic Resonance Mass Spectrometry (MRMS) technology enables scientists to see vital "hidden" information that is missing in data from other types of mass spectrometers. This advanced technology addresses the needs of specialists in a variety of focus areas that all desire efficient and precise solutions for their analytical problems. The unique value of this technology is Isotopic Fine Structure, resulting in unmatched confidence for compound identification that previously required guesswork.

solariX

solariX Specifications

  7T solariX 12T solariX 15T solariX
Maximum resolving power >10M >10M >10M
Mass accuracy (internal) 600 ppb 300 ppb 250 ppb
ESI    yes yes yes
MALDI optional optional optional
ETD optional optional optional
Detector ParaCell XR or 2xR ParaCell XR ParaCell XR
Magnetic Field 7T 12T 15T
Annual Cryogen Fill yes yes yes
Quench Line Required yes yes yes

„Coming from a background in MALDI Imaging with Bruker systems, there was only one instrument I wanted – the solariX MRMS. It gave me the opportunity to develop new methods and has been a very flexible workhorse instrument. We have been able to look at almost any biomolecule of interest, and it was key to developing the N-linked glycan workflows. We continue to use it in novel ways.”

Richard Drake, PhD, Professor and Director of the MUSC Proteomics Center, Medical University of South Carolina (MUSC), USA

“With our Bruker MRMS in Rouen the analysis of highly complex mixtures has been pushed further than ever and could also be made on a routine basis in the framework of the C2MC joint lab.”

Prof. Carlos Afonso, Professor of Chemistry, Université de Rouen-Normandie, and Dr. Pierre Giusti, TOTAL C2MC-Complex Matrices Molecular Characterization, Joint Laboratory, France